I/O module for CANopen® and CANopen FD®
- Communication profiles according to CiA® 301 version 4.2.0 and CiA® 1301 version 1.0.0
- Device profile according to CiA® 401 version 3.0.0
- High-speed CAN connection (ISO 11898-2)
- Selectable CANopen bit rates: Nominal: 20, 50, 125, 250, 500, 800, and 1000 kbit/s
- Selectable CANopen FD bit rates: Nominal: 250, 500, 800, and 1000 kbit/s, Data: 1, 2, 4, 5, 8, and 10 Mbit/s
- 2 LEDs "RUN" and "ERROR" for status indication according to CiA® DR 303-3
CAN (FD) Interface and settings
- NXP TJA1044GT CAN transceiver
- Galvanic isolation against the power supply up to 500 V
- Configuration of the CAN and CAN FD bit rates as well as the node ID with rotary switches on the casing
8 digital inputs
- Comply with the IEC 61131-2 standard
- Input characteristics: Type 3
- 2 groups of 4 inputs to be used either as sourcing or sinking inputs
- Galvanic isolation of the digital inputs 0 to 3 and 4 to 7 each up to 100 V against the module supply
8 digital outputs
- 500 mA load per High-side output
- Thermal protection per output
- Short circuit detection per output
- Open load detection in on-state and off-state per output
- Connections for CAN, I/O, and power supply via 5-pole screw-terminal strips (Phoenix)
- Plastic casing (width: 22.5 mm) for mounting on a DIN rail (DIN EN 60715 TH35)
- Voltage supply from 8 to 36 V